Saflame - Valves For Gas Controlsmall logo

Valves

Our range of Gas controls includes fully integrated Monoblock gas trains, individual solenoid valves, pressure switches, regulators, filters, ball valves, motorised butterfly valves and manual butterfly valves.
We can supply the entire Dungs range. The product included within this section is only a tiny part of what is available. Contact our sales team for more information.

Saflame recommend the use of Dungs Monoblock gas trains for most applications. Their compact size and ease of installation make conventional discrete gas trains seem archaic by comparison. The real benefits become apparent during commissioning and maintenance, The simplicity of exchanging and setting up a new unit means that downtime is reduced to a minimum and in the modern production environment, even a short interruption can be disastrous.

Dungs Monoblock Valves

 

 

 


MB-DLE 405 B07 230V
Part 53-01-01

 

MB-DLE 405 B07 110V
Part 53-01-01

A Double blocking Class 1 gas valve with integrated pilot bypass and pressure regulator. One of these plus an isolation valve is normally all you would need to equip a burner, in full compliance of the regulations.
Inlet / Outlet size - 1/2” BSP (Flange set required)
Max Inlet pressure - 360 mbar
Outlet pressure range - 4 – 20 mbar
Max Flow rate - 26 m3 @ 45 mbar Dp
 

MB-DLE 407 B07 230V
Part 53-01-03

 

MB-DLE 407 B07 110V
Part 53-01-04

A Double blocking Class 1 gas valve with integrated pilot bypass and pressure regulator. One of these plus an isolation valve is normally all you would need to equip a burner, in full compliance of the regulations.
Inlet / Outlet size - 3/4” BSP (Flange set required)
Max Inlet pressure - 360 mbar
Outlet pressure range - 4 – 20 mbar
Max Flow rate - 40 m3 @ 55 mbar Dp
 

MB-DLE 410 B07 230V
Part 53-01-05

 

MB-DLE 410 B07 110V
Part 53-01-06

A Double blocking Class 1 gas valve with integrated pilot bypass and pressure regulator. One of these plus an isolation valve is normally all you would need to equip a burner, in full compliance of the regulations.
Inlet / Outlet size - 1” BSP (Flange set required)
Max Inlet pressure - 360 mbar
Outlet pressure range - 4 – 20 mbar
Max Flow rate - 55 m3 @ 45 mbar Dp

Accessories

 

1/2" Flange set for 405.

Part 53-02-01

 
 

3/4" Flange set for 407.

Part 53-02-02

.
 

1" Flange set for 410..

Part 53-02-03

 
 

Coil for 405/407 110V.

Part 53-02-04

 
 

Coil for 405/407 230V.

Part 53-02-05

 
 

Coil for 410 110V

Part 53-02-06

 
 

Coil for 410 230V

Part 53-02-07

 
 

Fine Filter for 405/407

Part 53-02-08

 
 

Fine Filter for 410

Part 53-02-09

 
   
About Us | Site Map | Privacy Policy | Contact Us | ©2005 Saflame Ltd.