Saflame - Universal Burners small logo

Universal Burners

The Saflame range of Universal burners is suitable for a wide range of applications. With bodies available in both mild and stainless steel combined with high grade nickel alloy combustion chambers, the Universal burner provides unparalleled cost and performance. Applications range from the low contamination requirements of white ware, through to the high thermal input needs of a heat treatment furnace. Models are available for both LPG and natural gas and in a range of discharge velocities. we also provide spares.

 

1T Mild Steel Body
Part 51-01-01

  6T Mild Steel Body
Part 51-01-05.
 
1T Stainless Steel Body.
Part 51-01-02.
  6T Stainless Steel Body.
Part 51-01-06.
 
   
1 Therm / 29kW nominal output
390mm over all length
Air input 1 1/4” BSP
Air Max Flow 28m3/h / 1000ft3/h
Air Max Pressure 5mbar / 2” WG
Gas input 1/2” BSP
Max Flow (Nat) 2.8m3/h / 100ft3/h
Max Flow (Lpg) 1.1m3/h / 40ft3/h
Max Pressure (Nat) 10mbar / 4” WG
Max Pressure (Lpg) 7.2mbar / 2.9” WG
  6 Therm / 176kW nominal output
450mm over all length
Air input 1 1/2” BSP
Air Max Flow 170m3/h / 6000ft3/h
Air Max Pressure 12.4mbar / 5” WG
Gas input 3/4” BSP
Max Flow (Nat) 17m3/h / 600ft3/h
Max Flow (Lpg) 6.7m3/h / 235ft3/h
Max Pressure (Nat) 16.2mbar / 6.3” WG
Max Pressure (Lpg) 15.7mbar / 6.2” WG
 
3T Mild Steel Body.
Part 51-01-03.
  10T Mild Steel Body.
Part 51-01-07.
 
3T Mild Steel Body.
Part 51-01-03.
  10T Mild Steel Body.
Part 51-01-08.
 
   
3 Therm / 89kW nominal output
420mm over all length
Air input 1 1/4” BSP
Air Max Flow 84m3/h / 3000ft3/h
Air Max Pressure 3.7mbar / 1.5” WG
Gas input 1/2” BSP
Max Flow (Nat) 8.4m3/h / 300ft3/h
Max Flow (Lpg) 3.4m3/h / 120ft3/h
Max Pressure (Nat) 15.4mbar / 6.2” WG
Max Pressure (Lpg) 21.4mbar / 8.6” WG
  10 Therm / 293kW nominal output
685mm over all length
Air input 3” BSP
Air Max Flow 280m3/h / 10000ft3/h
Air Max Pressure 18.9mbar / 7.6” WG
Gas input 1” BSP
Max Flow (Nat) 28m3/h / 1000ft3/h
Max Flow (Lpg) 11m3/h / 390ft3/h
Max Pressure (Nat) 16.7mbar / 6.7” WG
Max Pressure (Lpg) 10.5mbar / 4.2” WG
 
Universal burner exploded view. Sight glass not fitted on all models.    
All models are suitable for either flame probe or UV flame detection and LPG or Natural gas. Please specify with order.
Ignition is by electrical spark.
For non standard lengths see the dimensions table.
  All thermal input are nominal and given under stoichmetric conditions. For applications requiring differing air/fuel ratios, a de-rating factor would need to be applied.
All burners are supplied WITHOUT gas train and controls
 
In addition to the standard length, all burners are available in custom lengths. The dimensions table at the end of this section shows what variations are available. If your application has just a thin wall or you need to reach through a tunnel kiln roof, we have the burner to suit. Just remember when you come to order spares, you need to tell us what size your burner is. A standard probe won’t reach the end of a 2 meter long special!
   
About Us | Site Map | Privacy Policy | Contact Us | ©2005 Saflame Ltd.