SAFLAME

Home | Service | Spares
Universal | Technical | Spares | Self Recuperative | Package Burners | Midi Spares | Maxi Spares
Auto | Semi Auto | Schemes | Valves | Pressure Switches | Motor Valves | Regulators Filters
Setpoint Controllers | Compact Controllers | Dicon 400 Controllers | Dicon 500 Controllers | Recorders | |
Proximity | Optical | Thermocouples | Accessories | Conversions | |
SCADA | Utilities | Data Acquisition | Omron | Communications | |
Temperature | Humidity | Pressure | Flow | Flue Gas Analysis | Accessories |
Valves | Couplings | Hoses | Filters | Flange | Lining | Parts
subglobal8 link | subglobal8 link | subglobal8 link | subglobal8 link | subglobal8 link | subglobal8 link | subglobal8 link

Saflame - Process Automationsmall logo

Data Acquisition

For all those little bits and peices you need for your SA8, indicator lenses, switches, fuses or even replacement labels :- contact our sales team.

Flame safeguard units are safety devices and should not be tampered with. All repairs should be performed by the manufacturers approved service centre.

 

Data Acquisition

AIID Digital 24

Part 56-01-07

24 Channel digital Input / Output module. Each channel is software configured as an input or output. 32bit 20Hz counters are available on each port.
Comms Via MODBus on RS485

Isolation - 500Vdc
Channels - 24
Input level - Logic 1 < 1V Logic 0 > 3V (30V max)
Output level - Open Collector, max 30mA 30V
Power - 2 watts 10-30 Vdc

AIID Analog 4

Part 56-01-08

4 Channel isolated analogue input module. Each input can be configured for Voltage, Current, Thermocouple (with CJC) or PRT.Each channel has a digital alarm output.

Isolation - 500Vdc Channel to Channel
Channels - 4
Input level - ±51.2mV, ±512mV, ±10.24V
4-20mA
TC, J,K,R,S,T,B,E
PRT100
Resolution - 16bit (accuracy ±0.025%)
Alarm Outputs - Open Collector, max 10mA 12V
Power - 3 watts 10-30 Vdc

AIID Analog 4/O

Part 56-01-09


4 Channel isolated analogue output module. Each output can be configured for Voltage or Current.

 

Isolation - 500Vdc Channel to Channel
Channels - 4
Output level - 4-20mA (250 to 500Ohms)
0-10V
Accuracy - ±0.1%)
Power - 4 watts 10-30 Vdc

AIID Analog 8

Part 56-01-10

8 Channel analogue Input module. Each channel is software configured as a Voltage or current input.

Comms Via MODBus on RS485

Isolation - 500Vdc
Channels - 8
Input level - ±1V, ±10V
4-20mA
Input Protection - 30V pk-pk
Resolution - 13bit (accuracy 0.05%)
Power - 2 watts 10-30 Vdc

AIID PC/485

Part 56-01-11

RS232 to RS485 convertor. For small networks it can derive it’s power from the PC but the facility is provided to connect an external supply if desired.

 

Isolation - 500Vdc
Baud rates - 2400 4800 9600 19200 38400
Max line length - 1.2km
Power - line 8mA, external 6V @ 40mA